I have a brand new RD600R. My installer said that there is an out of the box failure. There is no 24 VDC on the MV/Pump contact…which is where he is connecting a pump start relay switch wire. Are out of the box failures common on new units?
Hi Patrick,
We had some emails going to figure it out. For the readers wondering about this RD600 issue, here’s the result: The timer has a feature that turns on the pmp/mv circuit when a station is on. This feature can be turned on/off per station. The feature was simply turned off. Once turned on (see the manual), everything worked normally.
Thanks for the generous donation Patrick, I appreciate it.
Brian
I have reset my RD1200 both ways still no power. The valves turn on manually. It is only @3 years old. Any suggestions?
RD1200 ext-r blue
Hi Terry,
When you turn them on manually, do you mean manually at the valve itself, or using the manual function on the timer (Pressing the Manual On button after adding some minutes)?
Brian
At the valve.
I did lose power a few times this winter.
Ok, thanks. That helps. I’ll send u a separate email with som options…
hi, I have a RD-600-R. only using 2 stations. B station doesn’t always come on as programmed. any suggestions?
I sent you a separate email with some additional questions and info; if you didn’t get it, post back here and let me know. You might want to review the DIY Troubleshooting page for the programming tips and information. Stations have nunbers and schedules have letters.
thanks
Brian
My rd600-ext-r has one set of valves cooing like a dove and they continuously leak water if I turn the cap it leaks into the valve box but the cooing stops. What do I need repaired?
I sent you a separate email with some additional questions and info; if you didn’t get it, post back here and let me know.
thanks
Brian